Your Position: ShippingOnline.cn > Ship Supply > Products
Products
![]() |
DSHD-1792 Mercaptan Sulfur Tester
SP4332
china
15 Sep 2013
Brief Desctiption
A:Brief description:
DSHD-1792 Mercaptan Sulfur Tester is made according the national standard GB/T1792-88 Distillate fuels-Determination of mercaptan sulfur-Potentiometric titration method.
DSHD-1792 Mercaptan Sulfur Tester is composed of PHS-3C PH meter, 95-1 magnetic stirrer and support device.
Its function is to determine the mercaptan sulfur in jet fuel, gasoline, kerosene and light diesel without hydrothion, and the content is within the range of 0.0003~0.01%(m/m). Interferences will appear when elemental sulfur is over 0.0005%(m/m)
B:Technical parameters
DSHS-3C PH meter1. Grade of instrument: 0.012. Measurement range PH:(0~14.00)PH MV:(0~±1999)mV(automatically polarity display) Temp:(0~100.0)℃3. Minimum display unit: 0.01pH,1mV,0.1℃4. Compensated temperature range:(0~60)℃5. Basic error of electronic unit :PH:±0.01pH MV:±0.1%FS6. Basic error of instrument:pH:±0.02pH±1word Temp:±0.5℃±1word7. Incoming current of electronic unit: ≤ 2×10-12A8. Input resistance of electronic unit:≥1×1012Ω9. Compensated temperature error:±0.01pH10. Repeatability error of electronic unit :PH: ≤ 0.01pH MV: ≥ 1mV11. Repeatability error of instrument: ≤ 0.01pH12. Stability of electronic unit: ±0.01pH±1word/3h13. Overall dimension:290mm×210mm×95mm14. Weight:1.5kg15. Working condition: a) Ambient temperature:(5~40)℃ b) Relative humidity: ≤85% c) Power supply: AC(220±22)V,(50±0.5)Hz d) No obvious vibration e) No external magnetic field interference except earth magnetic field
DSHD-1792 Mercaptan Sulfur Tester is made according the national standard GB/T1792-88 Distillate fuels-Determination of mercaptan sulfur-Potentiometric titration method.
DSHD-1792 Mercaptan Sulfur Tester is composed of PHS-3C PH meter, 95-1 magnetic stirrer and support device.
Its function is to determine the mercaptan sulfur in jet fuel, gasoline, kerosene and light diesel without hydrothion, and the content is within the range of 0.0003~0.01%(m/m). Interferences will appear when elemental sulfur is over 0.0005%(m/m)
B:Technical parameters
DSHS-3C PH meter1. Grade of instrument: 0.012. Measurement range PH:(0~14.00)PH MV:(0~±1999)mV(automatically polarity display) Temp:(0~100.0)℃3. Minimum display unit: 0.01pH,1mV,0.1℃4. Compensated temperature range:(0~60)℃5. Basic error of electronic unit :PH:±0.01pH MV:±0.1%FS6. Basic error of instrument:pH:±0.02pH±1word Temp:±0.5℃±1word7. Incoming current of electronic unit: ≤ 2×10-12A8. Input resistance of electronic unit:≥1×1012Ω9. Compensated temperature error:±0.01pH10. Repeatability error of electronic unit :PH: ≤ 0.01pH MV: ≥ 1mV11. Repeatability error of instrument: ≤ 0.01pH12. Stability of electronic unit: ±0.01pH±1word/3h13. Overall dimension:290mm×210mm×95mm14. Weight:1.5kg15. Working condition: a) Ambient temperature:(5~40)℃ b) Relative humidity: ≤85% c) Power supply: AC(220±22)V,(50±0.5)Hz d) No obvious vibration e) No external magnetic field interference except earth magnetic field